So how exactly does this try to look for a system? Anything at all you'd change/increase/reorder? Do you concur with taping the seams in each layers of plywood?

I concur along with you: I'd like to see more details on this situation. I'm not mindful of any failures that have occurred in correctly dense-packed unventilated rafter bays.

Next, could you please validate this: "If you wish to use only one type of insulation in unvented rafter bays, you are restricted to spray polyurethane foam."

Now that I have defined the proper way to get it done, I may also Enable you to know that Lots of people have completed what you propose.

Although the GBA Web site already incorporates quite a few posts on The subject, we continue on to receive Recurrent questions on The easiest way to insulate a cathedral ceiling.

As I discussed during the write-up on this page, You can not use fluffy (air-permeable) insulation within an unvented roof assembly Except if you include things like rigid foam or spray foam previously mentioned the fluffy insulation.

Q. "I are actually employing rigid breadboard style expanded polystyrene during the rim joists and imagined a similar may very well be set beneath the sheathing between the rafter bays."

Not surprisingly, you can expect to continue to have thermal bridging through the rafters. But you won't have any dampness complications.

I have by now insulated the steep sides of my unvented mansard roof with six" fiberglass (And that i had it inspected), do you recommend I rip that out and use spray or board foam? I have gotten conflicting info on whether to deal with it being a wall or a roof.

The roof was shingles on t&g pine decking. Insulation was right up against that pine decking given that seventy seven and is also 2014. Things seems like it absolutely was put in yesterday. Not a nasty here are the findings location everywhere, no roof vents absolutely unvented roof.

Q. "For an unvented building without insulation earlier mentioned the sheathing, what about working with Wooden fibreboard involving the rafters immediately under and in contact with the sheathing?"

Investigating the fatal pic I experience there may very well be a simple although unorthodox Resolution. All of the rot from warm damp air meets cold Wooden is right near to wherever a vented hip could possibly have averted all and With out vent chutes.

to put in vent channels between the best on the rigid foam and the best layer of roof sheathing. I in no way page stated that it absolutely was necessary

Because the point from the string is earning roofs that don't fall short, there will be assemblies that basically do the job properly but are some a departure. If we article experienced the best possible practices that we could at any time imagine, now in hand and on task sites, we wouldn't be listed here (at GBA) and Martin would've considerably less to complete.